Overview

The Magnetic Resonance Facility has five solution-state NMR, one solid-state NMR, and one EPR spectrometers. The facility is located at the Molecular Science Building (MSB) 1421 and 1416. Members of the UCLA community, other academic institutions, and commercial enterprises may use the NMR and EPR spectrometers after training by the Magnetic Resonance Laboratory personnel.

Leadership

Contact

All users will have their grants recharged for use of the NMR spectrometers. Users from Departments other than Chemistry and Biochemistry must request a 6-digit recharge account prior to use of the spectrometers. 

Download application form

To learn more, please contact NMR training at nmr-training@chem.ucla.edu

Website: MIC Magnetic Resonance Facility

Equipment

NEO600

(Room 1416 Molecular Sciences)

  • For liquid samples
  • variable temperature capability
  • Running under TopSpin 4
  • Equipped with a 60-sample capacity sample changer
  • Probe:
    • 5 mm Prodigy broadband cryoprobe
    • ATM (Automatic Tune and Match)

AV400

(Room 1421 Molecular Sciences)

  • For liquid samples
  • Running under TopSpin 3.2
  • Used primarily with a 60 sample-capacity sample changer, running under iconnmr
  • Probe:
    • 5 mm broadband with Z gradient
    • ATM (Automatic Tune and Match)

AV600-SS

(Room 1141 Molecular Sciences)

  • For solid samples
  • Variable temperature capability
  • Running under TopSpin 3.5pl5
  • Probes:
    • 3.2 mm HXY CP/MAS probe ­ frequency ranges from 15N to 31P
    • 5 mm wide line probe ­ frequency ranges from 109Ag to 31P
    • 5 mm wide line probe 1H/19F
    • Manual tuning

AV300

(Room 1421 Molecular Sciences)

  • For liquid samples
  • Running under Topspin 2.1
  • Used primarily with a 60 sample-capacity sample changer, running under iconnmr
  • Probe:
    • 5 mm broadband with z gradient
    • ATM (automatic tune and match)

AV500

(Room 1421 Molecular Sciences)

  • For liquid samples
  • variable temperature capability
  • Running under TopSpin 3.5pl4
  • Equipped with a 24-sample capacity sample changer
  • Probes:
    • 5 mm dual cryoprobe: [13C, 1H]
    • Very high sensitivity for 13C
    • ATM (Automatic Tune and Match)

DRX500

(Room 1421 Molecular Sciences)

  • For liquid samples
  • variable temperature capability
  • Running under TopSpin 1.3
  • Probes:
    • 5 mm broadband with Z gradient
    • Manual tuning

EMXplus X-band CW EPR

(Room 1416 Molecular Sciences)

  • Variable temperature capability 4-600 K
  • High sensitivity optical resonator and premium microwave bridge
  • Running under Xenon EPR
  • Goniometer

Pricing

If your funding is managed in a department other than Chemistry and Biochemistry, please apply for a chemistry recharge account (download application form)

Except the AV400 and AV300 sample changers, our hourly fees are higher during normal working hours, and are as as follows:

AV600-SS

  • UCLA User: $36 (Day Rate), $18 (Night and Weekend Rate)
  • External Nonprofit: TBD
  • External Commercial: TBD

AV600

  • UCLA User: $36 (Day Rate), $18 (Night and Weekend Rate)
  • External Nonprofit: TBD
  • External Commercial: TBD

AV500

  • UCLA User: $48 (Day Rate), $24 (Night and Weekend Rate)
  • External Nonprofit: TBD
  • External Commercial: TBD

DRX500

  • UCLA User: $30 (Day Rate), $15 (Night and Weekend Rate)
  • External Nonprofit: TBD
  • External Commercial: TBD

AV400 Sample Changer

  • UCLA User: $24
  • External Nonprofit: TBD
  • External Commercial: TBD

AV300 Sample Changer

  • UCLA User: $13.50
  • External Nonprofit: TBD
  • External Commercial: TBD

EPR

  • UCLA User: $20.00
  • External Nonprofit: TBD
  • External Commercial: TBD

**Spectra Run Automatically Using the Sample Changer. Samples run on the AV400 and AV300 Sample Changer are charged for the amount of time actually used to run the sample. If the sample fails to run, there will be no charge.